Offices

Our offices are located at ENRC 2910 and 2920 providing a comfortable enviroment for study and reasearch.

   

Lab

Our lab is located at ENRC 2933 providing many reasearch equipments including semiconductor laser characterization system, FTIR and low-temperature controller, Raman spectroscopy , solar cell quantum efficiency testing system, hall system and microbiological lab.

   

Semiconductor laser characterization system

General laser diode measurements such as LI, spectrum, temperature dependence, polarization, IV, etc. are done using a specially designed probe station impedance matched for short pulsed testing. Translational stages allow for precise placement of a variety of optical components for quick adaptation allowing a variety of different measurements. Available equipment includes ILX Lightwave LDP-3840 & LDP-3811 Pulsed Current Sources, ILX LDT-5810B Temperature Controller, ILX OMM-6810B Optical Multimeter with Si (400-1100 nm) & InGaAs (950-1650 nm) Power/Waveheads, Keithley 2400 Source Meter for IV, & an Ando AQ-6315 Optical Spectrum Analyzer. A cleaving station with translational stages & a diamond tip is also available for cleaving laser bars as short as 200 microns with accuracy within 10 microns.

   

Solar cell testing system

The system includes two solar simulators, one spectrophotometer, several source meters and one probe station. The system is capable of measuring solar cell energy conversion efficiency as well the quantum efficiency. All measurements are fully automatic. The system can also be used for visible and near infrared photodetector response spectrum measurement.

   

FTIR and low temperature controller

A Nicolet 8700 FTIR spectrometer with LN2 cooled MCT detector and KBr beam splitter to cover wavelength range from 1um to 16 um. Two low cryostats are routinely used for low temperature optical characterizations for PL and EL measurements. The whole system is used to characterize Mid-IR laser and detectors. A Si liquid Helium cooled Si bolometer for THz measurement will be added soon.

   

Ellipsometry

One of the advanced techniques to measure the optical properties of different materials is Ellipsometry. Using the Ellipsometer we are able to measure the parameters such as optical constants, dielectric constant and thickness of the sample under investigation. The optical behavior of materials could be studies from UV to NIR spectrum range starting from 200 nm to 2500 nm. This Ellipsometer has also the capability of temperature dependence measurements which can be done in an specific heatcell.

   

Micro PL-Micro Raman spectroscopy

The Micro PL-Micro Raman spectroscopy setup is a home-made system provided to measure the PL and Raman spectrum in UV/Vis range. This setup includes 3 different lasers for different excitation wavelengths and powers. Lasers such as He-Ne laser (633 nm), DPSS green laser (532 nm) and especially a Nd:Yag pulsed laser (1064 nm, 532 nm, 355 nm, and 266) for high excitation power. iHR520 Horiba spectrometer including 3 grating with different groove densities to afford desired spectrum resolution. This setup is facilitated by a LN2-cooled Si CCD detector and a photomultiplier tube and capable of measuring PL and Raman spectrum from 200 to 1000 nm range.

   

Infrared PL System

A home-made infrared photoluminescence (PL) spectroscopy setup is constructed to measure PL spectra of semiconductors from 1000 nm to 2500 nm spectral range. This setup includes a femtosecond (fs) Ti: sapphire laser and a DPSS CW laser sources. The wavelength of the fs laser varies from 690 nm to 1040 nm and it provides a high optical pumping power up to 3.5 W (in 800 nm wavelength). The CW laser is a 532 nm green laser. This setup has the capability to be used as off-axis PL and MicroPL configuration. A microscopic compatible cryostat enables the temperature dependent PL measurements for micro scale devices.

   

Ultra high vacuum Chemical Vapor Deposition system

Funded by ARO and ARL, Dr. Yu and Dr. Naseem have built one unique UHV-CVD system. This new system is dedicated for epitaxy growth of SiGeSn materials for next generation Si photonics device applications.

   

Electron Beam Lithography

One dedicated JEOL JBX-5500ZD electron beam lithography writer purchased by our NSF EPSCoR project was installed in High Density Electronics Center (HiDEC) at University of Arkansas, Fayetteville. This will greatly enhance our nano-fabrication capability in campus.

   

Hall measurement system

Room temperature Hall measurement and resistivity measurement system. Low temperature measurement capability will be added later.


   

Microbiological lab

General microbiological experiments such as bacterial culture, plaque assay, etc. are done in microbiological lab for short pulsed testing. Safe manipulation to microorganisms could be achieved in Biosafety cabinet. Autoclave is used for multipurpose sterilizations. Incubator allows the microorganisms growing very fast at proper temperature. Also refridgerator, vortexer, spectrophotometer, water purifier system, stirrer are available in lab.

   

Device Simulation Packages

Crosslight, RSoft FDTD packages, and Silvaco are used for various optoelecronic and photonic devices simulation.

   
Copyright © Applied nano & Bio photonics group